Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Circulation Journal ; (12): 15-19, 2016.
Article in Chinese | WPRIM | ID: wpr-486943

ABSTRACT

Objective: To systemically review the safety and efficacy of Absorb bioresorbable vascular scaffold (Absorb BVS) versus cobalt chromium-everolimus eluting stent (CoCr-EES) for treating the patients with coronary artery disease (CAD) by percutaneous coronary intervention (PCI). Methods: We searched relevant literatures in PubMed, Embase, Cochrane Library, CNKI and Wanfang database from 2008-01 to 2015-10, meanwhile, collected published data and randomized controlled trials from meeting abstracts and websites to compare Absorb BVS and CoCr-EES for treating CAD patients. The quality of literatures were assessed and extracted by modiifed Jadad score, Meta-analysis was conducted by STATA 12.0 soft ware. Results: There were 4 eligible trials with 3,389 patients were enrolled. Absorb BVS group, n=2,164 and CoCr-EES group, n=1,225. During the mean of 1.1 years follow-up period, the following incidences were similar between 2 groups:target lesion failure (OR=1.29, 95%CI 0.95-1.74, P=0.10), all cause death (OR=1.31, 95%CI 0.60-2.87, P=0.50), cardiac death (OR=1.38, 95%CI 0.45-4.24, P=0.57), myocardial infarction (OR=1.30, 95%CI 0.93-1.80, P=0.12), deifnite or probable stent thrombosis (OR=2.08, 95%CI 0.95-4.54, P=0.07), re-vascularization (OR=1.03, 95%CI 0.80-1.33, P=0.81), target lesion re-vascularization (OR=1.06, 95%CI 0.67-1.66, P=0.81) and the patient-oriented composite endpoint (OR=0.95, 95%CI 0.66-1.35, P=0.76). Conclusion: Absorb BVS and CoCr-EES had the similar safety and efifcacy for treating the low and moderate risk CAD patients who had angina, ischemia while without symptoms. The longer period of follow-up study and larger randomized, controlled clinical trials were needed for Absorb BVS application in clinical practice.

2.
Chinese Circulation Journal ; (12): 639-643, 2015.
Article in Chinese | WPRIM | ID: wpr-465106

ABSTRACT

Objective: To systematically review the safety and efifciency for dual antiplatelet therapy (DAPT) ≤ 6 months and DAPT ≥ 12 months in patients after drug eluting stent (DES) implantation. Methods: We collected the data for randomized clinical trials for DAPT ≤ 6 months and DAPT ≥ 12 months in patients after DES implantation up to 2015-01 by searching the literatures of PubMed, EMBASE, Cochrane Library, Scopus and Chinese literature database, and meanwhile collected the relevant reporting cases from both domestic and international cardiovascular conferences for this study. There were 2 investigators independently conducted the literature screening, data extraction and quality evaluation, Meta analysis was performed with STATA 12.0 software. Results: A total of 15,378 patients from 7 eligible studies were enrolled and the patients were divided into 2 groups: DAPT ≤ 6 months group,n=7672 and DAPT ≥ 12 months group,n=7706. Meta analysis indicated that DAPT ≤ 6 months could effectively reduce the major bleeding (OR=0.58, 95% CI 0.37-0.91,P=0.017). While the other incidences between 2 groups were similar as all cause death (OR=0.90, 95% CI 0.73-1.11,P=0.314), cardiac death (OR=0.93, 95% CI 0.70-1.24,P=0.617), myocardial infarction (OR=1.13, 95% CI 0.91-1.41,P=0.275), in stent thrombosis (OR=1.21, 95% CI 0.79-1.85,P=0.382) and cerebrovascular accidents (OR=1.00, 95% CI 0.66-1.51,P=1.000). Conclusion: The incidence rates of cardiovascular and cerebrovascular events are similar in patients with DAPT ≤ 6 months and DAPT ≥ 12 months after DES implantation. DAPT ≤ 6 month had the lower risk of bleeding, which is rather suitable for the patients received new generation of DES, with higher risk of bleeding, lower risk of thrombosis and with poor compliance to medication; however, the large and randomized clinical trials are needed to make ifnal conclusion.

SELECTION OF CITATIONS
SEARCH DETAIL